Double Doors Wall Mounting Enclosure PTD

Double Doors Wall Mounting Enclosure PTD

The Double Doors Wall Mounting Enclosure PTD is designed to house electrical distribution, control, and automation equipment in installations requiring convenient front access and organized internal space. Its double-door structure provides access to a wider internal working area, making it suitable for arranging circuit breakers, contactors, PLCs, terminal blocks, and other electrical components. The wall-mounted design helps save floor space, while the internal mounting plate supports structured component installation and wiring. The enclosure can be configured according to equipment dimensions, cable entry requirements, and installation conditions for industrial control panels, power distribution systems, and machine automation applications.
Send Inquiry
Performance of Double Doors Wall Mounting Enclosure PTD
 
  • IP66 Protection Against Dust and Water

The enclosure features a grooved body edge that works with the door sealing gasket to help prevent dust and water from entering the internal compartment. The bottom gland plate is also fitted with a sealing gasket to maintain the specified IP66 protection when properly assembled.

  • Polyurethane Foam Sealing System

A PU foam gasket is fitted inside the door to create a continuous sealing interface between the door and enclosure body. This design supports consistent contact between the sealing surfaces and helps protect internal electrical components from environmental exposure.

  • Reinforced Door Structure for Component Installation

For enclosures above 600 mm in height, vertical reinforcement strips with pre-punched mounting holes are welded to both sides of the door. These provide convenient fixing points for compatible door-mounted components using M4 self-tapping screws.

Performance of Double Door Wall Mount Enclosures
 
  • Wide-Opening Door with Pin-Type Hinges

The pin-type hinge design allows the door to open up to 130°, providing better access to the internal mounting plate, electrical components, and wiring area during installation and maintenance.

  • Convenient Wall-Mounting Design

Four pre-formed mounting holes are provided on the rear panel to simplify wall installation. Optional wall-mounting brackets can also be used according to the installation method and supporting structure.

  • Cold-Rolled Steel Construction with Textured Powder Coating

The enclosure is manufactured from cold-rolled sheet steel, with panel thickness selected according to enclosure height and structural requirements. A thermosetting epoxy powder coating with a textured finish is available in RAL 7035 or RAL 7032, providing a consistent exterior finish and surface protection.

Performance of Double Door Wall Mount Enclosures

Customization Services for Double Door Wall Mount Enclosures

 
  • Enclosure Dimensions & Sheet Thickness

The enclosure height, width, and depth can be configured according to the electrical equipment layout and available installation space. Cold-rolled steel thickness can be selected according to cabinet dimensions and structural requirements, with door, body, and mounting plate specifications coordinated for the intended application.

  • Cable Entry & Gland Plate Configuration

The bottom gland plate can be configured according to cable quantity, cable dimensions, and entry direction. Gland plate openings and sealing arrangements can be coordinated with the wiring plan to help maintain the required IP66 protection after installation.

  • Internal Mounting & Door Layout

The internal mounting plate and door layout can be adapted to the component arrangement. Mounting holes, equipment cutouts, and door-mounted component positions can be prepared according to approved drawings to support electrical assembly and wiring.

  • Surface Finish & Installation Options

The enclosure can be finished with textured thermosetting epoxy powder coating in RAL 7035 or RAL 7032. Wall-mounting arrangements can be selected according to site requirements, including the use of suitable mounting brackets. Locking hardware and other installation details can be confirmed during specification review.

 

FAQ

 

When should I choose a double-door enclosure instead of a single-door enclosure?
A double-door enclosure can be considered when the electrical assembly requires a wider front access area or when the equipment layout makes access through a single door less convenient. The choice depends on cabinet width, component arrangement, and available operating space.

 

Can the enclosure accommodate both power distribution and control components?
Yes. Distribution and control components can be housed in the same enclosure when the internal space, electrical design, heat dissipation requirements, and wiring arrangement are appropriately planned.

 

How should the enclosure be selected for heavy electrical equipment?
Selection should account for the combined weight of the enclosure and installed components, the mounting surface, fixing-point arrangement, and the loads applied during operation. The supporting wall and mounting hardware should be suitable for the intended installation.

 

How can heat buildup inside the enclosure be managed?
Thermal requirements depend on component power losses, ambient temperature, enclosure size, and operating conditions. Heat dissipation should be assessed during the electrical design stage, since ventilation openings may affect the specified IP66 protection.

 

 

Hot Tags: double doors wall mounting enclosure ptd, China, manufacturers, suppliers, factory, customized, wholesale, Custom enclosures for electrical control systems, Durable metal protection box, IP66 Waterproof Electrical Distribution Box, Protection cabinet for electrical components, Steel Electrical Control Panel Enclosure, Weather resistant enclosure box