Stainless Steel Electrical Enclosure
Compared with ordinary carbon steel cabinets, stainless steel electrical cabinets are more adaptable to extreme environments. They have passed IP66/IP67 protection level certification, can completely block dust intrusion, and withstand strong water splashes and short-term immersion; at the same time, they meet NEMA 4 standards and have excellent corrosion resistance, so they perform well in high humidity, high salt fog or strong corrosion scenes such as chemical plants, coastal facilities, and nuclear power plants. In terms of service life and maintenance cost, the natural corrosion resistance of stainless steel means that it does not require additional coating protection, greatly reducing the frequency and cost of maintenance. Under normal use, the service life can reach more than 20 years, reducing the long-term operating burden for enterprises and providing a long-lasting and stable equipment protection solution.
In the production of Stainless Steel Electrical Enclosure, the first priority is raw material screening. We use 304/316 stainless steel plates that meet the ASTM A240 standard, with a thickness of 1.2-3.0mm and customized on demand. After entering the factory, the alloy composition is verified by a spectrometer, and the hardness test is ensured to meet the standard. Mechanical or electrolytic polishing pretreatment removes oil and oxide layer to improve surface rust resistance.

2. Precision machining and forming

The pretreated plates enter the CNC machining stage. The laser cutting machine cuts the parts with an accuracy of ±0.1mm, and the CNC bending machine controls the bending angle error within ±0.5° to shape the box structure. Complex parts use stamping technology to ensure dimensional consistency and structural strength.
After the parts are formed, professional welders use argon arc welding or gas shielded welding to ensure that the welds are uniform and defect-free, and the strength reaches more than 85% of the parent material. Post-welding grinding removes burrs and protrusions, taking into account both aesthetics and safety.

4. Quality inspection and protective treatment

The finished product must undergo multiple inspections: appearance inspection to ensure flawlessness, IP protection test to verify dust and water resistance, airtightness inspection to prevent leakage; special scenario products must also pass salt spray and high temperature resistance tests. After passing the inspection, anti-corrosion paint is sprayed and passivation treatment is performed to enhance corrosion resistance and produce high-quality cabinets.
SS Steel Electrical Enclosure Selection Table
| Chassis Depth(D)150mm | ||||||||||
| (H)mm | 200 | 250 | 300 | 250 | 300 | 400 | 400 | 500 | 600 | 600 |
| (W)mm | 200 | 200 | 250 | 250 | 300 | 300 | 400 | 400 | 400 | 500 |
| H1)mm | 165 | 215 | 265 | 215 | 265 | 365 | 365 | 465 | 565 | 565 |
| (W1)mm | 150 | 150 | 200 | 200 | 250 | 250 | 350 | 350 | 350 | 450 |
| (Model) | PTX2 215 | PTX2 2515 | PTX25 315 | PTX25 2515 | PTX3 315 | PTX3 415 | PTX4 415 | PTX4 515 | PTX4 615 | PTX5 615 |
| Chassis Depth(D)200mm | ||||||||||
| (H)mm | 300 | 300 | 400 | 400 | 500 | 600 | 600 | 700 | 800 | 800 |
| (W)mm | 200 | 300 | 300 | 400 | 400 | 400 | 500 | 500 | 600 | 800 |
| (H1)mm | 265 | 265 | 365 | 365 | 465 | 565 | 565 | 665 | 765 | 765 |
| (W1)mm | 150 | 250 | 250 | 350 | 350 | 350 | 450 | 450 | 550 | 750 |
| (Model) | PTX2 320 | PTX3 320 | PTX3 420 | PTX4 420 | PTX4 520 | PTX4 620 | PTX5 620 | PTX5 720 | PTX6 820 | PTX8 820 |
| Chassis Depth(D)250mm | ||||||||||
| (H)mm | 400 | 500 | 500 | 600 | 500 | 600 | 800 | 800 | 1000 | 1200 |
| (W)mm | 300 | 300 | 400 | 400 | 500 | 500 | 600 | 800 | 800 | 800 |
| (H1)mm | 365 | 465 | 465 | 565 | 465 | 565 | 765 | 765 | 965 | 1165 |
| (W1)mm | 250 | 250 | 350 | 350 | 450 | 450 | 550 | 750 | 750 | 750 |
| (Model) | PTX3 425 | PTX3 525 | PTX4 525 | PTX4 625 | PTX5 525 | PTX5 625 | PTX6 825 | PTX8 825 | PTX8 1025 | PTX8 1225 |
| Chassis Depth(D)300mm | ||||||||||
| (H)mm | 400 | 500 | 500 | 600 | 600 | 700 | 800 | 800 | 1000 | 1200 |
| (W)mm | 300 | 300 | 400 | 400 | 500 | 500 | 600 | 800 | 800 | 800 |
| (H1)mm | 365 | 465 | 465 | 565 | 565 | 665 | 765 | 765 | 965 | 1165 |
| (W1)mm | 250 | 250 | 350 | 350 | 450 | 450 | 550 | 750 | 750 | 750 |
| (Model) | PTX3 430 | PTX3 530 | PTX4 530 | PTX4 630 | PTX5 630 | PTX5 730 | PTX6 830 | PTX8 830 | PTX8 1030 | PTX8 1230 |
| (D)400mm | ||||||||||
| (H)mm | 600 | 700 | 800 | 800 | 1000 | 1000 | 1000 | 1200 | 1200 | 1200 |
| (W)mm | 500 | 500 | 600 | 800 | 600 | 800 | 1000 | 600 | 800 | 1000 |
| (H1)mm | 565 | 665 | 765 | 765 | 965 | 965 | 965 | 1165 | 1165 | 1165 |
| (W1)mm | 450 | 450 | 550 | 750 | 550 | 750 | 950 | 550 | 750 | 950 |
| (Model) | PTX5 640 | PTX5 740 | PTX6 840 | PTX8 840 | PTX6 1040 | PTX8 1040 | PTX10 1040 | PTX6 1240 | PTX8 1240 | PTX10 1240 |
Application
Stainless Steel Electrical Enclosure for Industrial Automation Control
In industrial automation, stainless steel electrical cabinets are designed to protect precision equipment such as PLCs, sensors, and inverters. Its IP65 + protection level can resist erosion by coolants, lubricants, and metal debris, and its sturdy structure can withstand mechanical vibrations, reducing the risk of production line downtime, and is suitable for scenarios such as automotive manufacturing and electronic assembly.
Stainless Steel Electrical Enclosure for Chemical Plant Equipment
In chemical plant environments, 316-grade stainless steel electrical cabinets can resist strong corrosive media such as sulfuric acid and hydrochloric acid due to the corrosion resistance of molybdenum. The sealing and explosion-proof design meets industry safety standards, providing reliable protection for reactor control circuits and pipeline monitoring equipment to avoid safety hazards caused by electrical failures.




Stainless Steel Electrical Enclosure for Food Processing Machinery
In the field of food processing, stainless steel electrical cabinets meet NSF/ANSI 3-A hygiene standards due to their non-porous surfaces, can withstand frequent cleaning with high-temperature water and disinfectants, and prevent bacterial growth and raw material contamination. Commonly used in baking, meat processing, and other scenarios, they ensure stable operation of equipment in humid and greasy environments and reduce cleaning and maintenance costs.
Stainless Steel Electrical Enclosure for Outdoor Public Facilities
In outdoor scenes, stainless steel electrical cabinets can withstand rainstorms and dust with IP66/IP67 protection levels, 304/316 materials can resist salt spray corrosion, and the solid structure can prevent external impact. It is suitable for street lights and traffic signal control systems, reducing the frequency of municipal maintenance and extending the service life of outdoor equipment.

Choose us
We Will Be Your Best SS Steel Electrical Enclosure Manufacturer. Our enclosures, crafted from high-grade stainless steel, offer exceptional corrosion resistance and durability, ensuring reliable protection for your electrical components even in the harshest environments. With a dedicated team committed to precision engineering and prompt customer support, we guarantee seamless production, timely delivery, and a partnership that exceeds your expectations.
FAQ:
1. What is the material grade and anti-corrosion performance of the wall-mounted stainless steel Enclosure?
The mainstream uses 304 or 316 stainless steel, of which 316 has better corrosion resistance in chloride ion environments (such as coastal and chemical scenes). The surface treatment can be RAL 7035/7032 industrial spraying or primary color brushing to ensure salt spray resistance, acid and alkali resistance. Some high-demand scenes (such as offshore platforms) must comply with NEMA 4X standards (anti-corrosion certification).
2. Does the protection level (IP) meet the harsh environment?
Most SS Wall-Mount Enclosures products are marked with IP66/IP67
IP66: Completely dustproof and resistant to strong water spray (suitable for outdoor and dusty workshops)
IP67: Short-term immersion waterproof (suitable for humid and flushing environments).
Note: NEMA 4 standard (American standard) is equivalent to IP66 and can be referenced interchangeably.
3. Customization capabilities and delivery cycle?
Size: Standard product, also supports non-standard customization
Function: Can integrate cable management, cooling fan, explosion-proof interface, etc.410
Delivery: Small batch orders are about 7-15 working days, orders over 5,000 pieces require 25 days (depending on complexity).
4. Applicable scenarios and installation methods?
Typical scenarios:
Industry: PLC control / floor standing electrical cabinet , power distribution box
Infrastructure: subway tunnel emergency telephone box (IP55 anti-destruction design)
Outdoor: solar power distribution cabinet, street equipment box (mainly wall-mounted)
Installation: Standard wall-mounted bracket, some models support floor installation.
5. Supplier qualifications and quality control?
We have a variety of key certifications:
ISO 9001 (quality management system)
UL/CE (European and American electrical safety certification)56
Quality inspection requirements:
Material needs to provide SGS report (verification of stainless steel composition)
Finished products pass salt spray test (≥500 hours) and pressure seal test.
Hot Tags: stainless steel electrical enclosure, China, manufacturers, suppliers, factory, customized, wholesale, Metal Junction Boxes Screws Type, Metal Knock Down Type Cabinets, Stainless Steel Box With Inner Door Toughened Glass Door, Control Desks AM 2, IP66 Stainless Steel Outdoor Distribution Box, Control Panels Enclosure With Double Doors
You Might Also Like